Part number WE-3996 - Transformer Power with NSN 5950013173101 under 5950 Coils and Transformers is now available and ready for immediate shipping. Sourced from Wems Inc, you can easily order part number WE-3996 at a competitive price. To get a quick quote for this part, just fill out the form.
Please make sure to fill out the form below as carefully and completely as possible. Pay attention to the asterisk (*) marked fields, as your response will determine the majority of your quote. A sales representative will contact you within 15 of receiving your request.
Note : We will not share your information to any third parties.
Aerospace Aces, owned and operated by ASAP Semiconductor, is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited distributor of Wems Inc obsolete and hard-to-find parts. We are the only independent distributor with a No China Sourcing Pledge, so you can trust us to help you get the highest quality parts and NSNs.
The NSN, or National Stock Number, is a 13-digit serial number assigned to items of the federal supply chain by the Defense Logistics Agency (DLA) and used by all members of the North Atlantic Treaty Organization (NATO) and the United States Department of Defense. If you have any questions about NSN 5950013173101, or would like to expedite your quote, please feel free to call us at our toll-free number, +1-714-705-4780, or email us at sales@aerospaceaces.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-317-3101 Item Description: Transformer Power | 5950 | 013173101 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
We-3996 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.365 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
ADAT | BODY WIDTH | 2.775 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.035 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 198.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.05 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE TERTIARY |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 353.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.43 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 1.79 KILOVOLT-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 28.13 VOLTS-AMPERES SINGLE COMPONENT SINGLE TERTIARY |
CRMJ | WINDING POWER RATING | 59.73 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 13.72 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE TERTIARY |
CWJS | WINDING OPERATING VOLTAGE | 18.10 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 27.15 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.05 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS; TERMINALS 23 AND 24 SPLIT FOR DUAL CONNECTION; TERTIARY WINDING TIED TO THE FOURTH SECONDARY WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 1 BUS (BAR) CONDUCTOR AND 22 PIN AND 2 RIBBON |
ADAQ | BODY LENGTH | 3.600 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT AND 1 TERTIARY SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 116.38 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3.2 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.308 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.328 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.271 INCHES MINIMUM SINGLE GROUP AND 0.276 INCHES MAXIMUM SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 226.24 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 9.05 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 82577-H940081 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |