Part number APL1111 6584 1 - Circuit Breaker with NSN 5925011083572 under 5925 Circuit Breakers is now available and ready for immediate shipping. Sourced from Sensata Technologies Inc, you can easily order part number APL1111 6584 1 at a competitive price. To get a quick quote for this part, just fill out the form.
Please make sure to fill out the form below as carefully and completely as possible. Pay attention to the asterisk (*) marked fields, as your response will determine the majority of your quote. A sales representative will contact you within 15 of receiving your request.
Note : We will not share your information to any third parties.
Aerospace Aces, owned and operated by ASAP Semiconductor, is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited distributor of Sensata Technologies Inc obsolete and hard-to-find parts. We are the only independent distributor with a No China Sourcing Pledge, so you can trust us to help you get the highest quality parts and NSNs.
The NSN, or National Stock Number, is a 13-digit serial number assigned to items of the federal supply chain by the Defense Logistics Agency (DLA) and used by all members of the North Atlantic Treaty Organization (NATO) and the United States Department of Defense. If you have any questions about NSN 5925011083572, or would like to expedite your quote, please feel free to call us at our toll-free number, +1-714-705-4780, or email us at sales@aerospaceaces.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-108-3572 Item Description: Circuit Breaker | 5925 | 011083572 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
APL1111 6584 1 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 4 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC THIRD LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 DC FOURTH LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC THIRD LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT THIRD LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | UNDERVOLTAGE FOURTH LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC FIRST LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC THIRD LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS FOURTH LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY THIRD LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 FIRST LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 THIRD LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, AND FOUR LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP FOURTH LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT FIRST LOCATION AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT SECOND LOCATION AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT THIRD LOCATION AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
FREQ | FREQUENCY IN HERTZ | 400.0 FIRST LOCATION |
FREQ | FREQUENCY IN HERTZ | 400.0 SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 400.0 THIRD LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 12.500 OUNCES |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 10 THREADED STUD |
APLA1X
parker hannifin ltd
2510016753755 (2510-01-675-3755)
platemounting
CAGE Code 30780
2510 Vehicle Cab Body Frame Structural Components
|
APL320320012
engineered air systems inc
3030001608286 (3030-00-160-8286)
belts v matched set
CAGE Code 90598
3030 Belting Drive Belts Fan Belts and Accessories
|
APL23064-1011
aircraft parts corporation
3040008902743 (3040-00-890-2743)
shaft dampener driv
CAGE Code 32970
3040 Miscellaneous Power Transmission Equipment
|
APLG1002
dresser rand company
4820014072978 (4820-01-407-2978)
stem fluid valve
CAGE Code 93236
4820 Valves Nonpowered
|
APL22-3
anillo industries inc
5310001596298 (5310-00-159-6298)
washer flat
CAGE Code 10630
5310 Nuts and Washers
|
APL22-3
asc international inc
5310001596298 (5310-00-159-6298)
washer flat
CAGE Code 06329
5310 Nuts and Washers
|
APL8 62P1 M
milton manufacturing inc
5315016011820 (5315-01-601-1820)
pin quick release
CAGE Code 3DHG6
5315 Nails Keys and Pins
|
APL8 62P1 M
pivot point incorporated
5315016011820 (5315-01-601-1820)
pin quick release
CAGE Code 0CUJ4
5315 Nails Keys and Pins
|
APL253-1
ap labs inc
5920014627431 (5920-01-462-7431)
fuse inclosed link
CAGE Code 1Z496
5920 Fuses Arresters Absorbers and Protector
|
APL33-21238-1
sensata technologies inc
5925009014931 (5925-00-901-4931)
circuit breaker
CAGE Code 81541
5925 Circuit Breakers
|
APL3-24701-10
sensata technologies inc
5925011395372 (5925-01-139-5372)
circuit breaker
CAGE Code 82647
5925 Circuit Breakers
|
APL5111-1REC2-3235-3
sensata technologies inc
5925001488124 (5925-00-148-8124)
circuit breaker
CAGE Code 81541
5925 Circuit Breakers
|
APL5-292-2
sensata technologies inc
5925004208348 (5925-00-420-8348)
circuit breaker
CAGE Code 81541
5925 Circuit Breakers
|
APL3331 5129 1
sensata technologies inc
5925010743043 (5925-01-074-3043)
circuit breaker
CAGE Code 81541
5925 Circuit Breakers
|
APL311111-1B-RR-466-2
sensata technologies inc
5925000802279 (5925-00-080-2279)
circuit breaker
CAGE Code 81541
5925 Circuit Breakers
|
APL53-155-2
sensata technologies inc
5925002453391 (5925-00-245-3391)
circuit breaker
CAGE Code 81541
5925 Circuit Breakers
|
We Hope You'll Choose Us as Your Parts Distributor In the Future. Don’t forget That We offer Competitive Quotes and Same-Day Shipping On Most of Our Inventory.
Request for Quote